Welcome to visit Yunhua!
Current location:front page >> mechanical

How to vent valve for household floor heating

2025-12-04 05:58:26 mechanical

How to vent valve for household floor heating

With the advent of winter, the frequency of use of household floor heating gradually increases. As a key component of the floor heating system, the operation and maintenance of the exhaust valve have become the focus of many users. This article will introduce in detail the function, operation method and solutions to common problems of household floor heating exhaust valves to help you better maintain your floor heating system.

1. The function of exhaust valve

How to vent valve for household floor heating

The main function of the exhaust valve is to remove air from the floor heating pipes and ensure smooth circulation of hot water. If there is air in the pipes, it will cause uneven heat dissipation, temperature drops and even system damage. Therefore, regular exhaust is an important step to ensure efficient operation of floor heating.

Exhaust valve typeApplicable scenariosFeatures
Automatic exhaust valveWhole house floor heating systemNo manual operation required, air is automatically removed
Manual exhaust valveLocal underfloor heating or older systemsUsers are required to manually exhaust the gas regularly

2. Operation steps of exhaust valve

The following are the specific operating steps of the manual exhaust valve:

stepsOperating Instructions
1Turn off the power to the floor heating system to ensure safety
2Locate the exhaust valve location (usually located above the manifold)
3Use a screwdriver or special tool to gently loosen the exhaust valve screw
4Wait for the air to escape until water comes out
5Tighten the exhaust valve screw to restore system operation

3. Common problems and solutions

When using the exhaust valve, you may encounter the following problems:

questionReasonsolution
Exhaust valve leakingThe sealing ring is aging or the screws are not tightenedReplace the sealing ring or retighten the screws
Floor heating is still not hot after exhaustBlocked pipes or insufficient system pressureCheck the pipes or contact a professional
Exhaust valve cannot be openedValve core is corroded or damagedReplace exhaust valve

4. Maintenance recommendations for exhaust valves

In order to extend the service life of the exhaust valve, it is recommended to perform the following maintenance regularly:

maintenance itemsFrequencyThings to note
Check exhaust valve sealingonce a monthMake sure there are no leaks
Manual exhaust operationQuarterlyAvoid frequent operations
Clean exhaust valveonce a yearPrevent impurities from clogging

5. Summary

The exhaust valve is an indispensable component of the home floor heating system. Correct operation and maintenance can significantly improve the efficiency and life of the floor heating. Through the introduction of this article, I hope you can master the use of the exhaust valve and solve it in time when you encounter problems. If you are not familiar with the operation, it is recommended to contact professionals for maintenance to ensure safe operation of the system.

Next article
  • What is BIS sensorIn today's rapidly developing technological era, sensor technology has become an indispensable part of all walks of life. As an important sensor type, BIS sensors have received widespread attention in recent years. This article will introduce in detail the definition, working principle, application fields of BIS sensors, as well as hot topics and hot content in the past 10 days.1. Definition of BIS
    2026-01-18 mechanical
  • What is ammonia nitrogen?Ammonia nitrogen is a common pollutant in water bodies, mainly composed of ammonia (NH₃) and ammonium ions (NH₄⁺). It is one of the important indicators for evaluating water quality. Excessively high concentrations of ammonia nitrogen can cause harm to aquatic ecosystems and human health. This article will introduce in detail the sources, hazards, detection methods and recent hot topics
    2026-01-15 mechanical
  • What does gas ppm mean?In the fields of environmental monitoring, industrial safety and health,ppm(parts per million) is a common concentration unit used to express the content of gas in the air. This article will explain the meaning, application scenarios and related data of ppm in detail to help readers better understand this concept.1. Definition of ppmppm is the abbreviation of "parts per million" and represents
    2026-01-13 mechanical
  • How to install floor heating pipes on the wallIn recent years, floor heating systems have been favored by more and more families because of their comfort and energy saving. However, in addition to the traditional floor laying method, the installation of floor heating pipes on the wall has gradually become a new option. This article will introduce in detail the installation method of floor heating pipes on the wall, a
    2026-01-10 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line