What should I do if the end of the heater is not hot? A summary of popular solutions across the network

With the arrival of winter, lack of heating has become a headache for many families. Especially the end of the heater is not hot, which affects the overall heating effect. This article combines the hot discussions and expert suggestions on the Internet in the past 10 days to sort out a set of system solutions for you.

1. Common reasons why the heater end is not hot

What should I do if the end of the heater is not hot?

Reason typeSpecific performanceprobability of occurrence
Air blockageThe end radiator is not hot at all45%
hydraulic imbalanceThe further away from the boiler, the less hot it is30%
clogged pipesThe radiator is partly hot and partly cool15%
Valve failureRegulating valve does not respond8%
OthersSystem design issues, etc.2%

2. Step-by-step troubleshooting and solutions

Step 1: Exhaust Treatment

This is the most common and easiest solution. Find the exhaust valve on the top of the radiator and turn it slowly with a screwdriver until water flows out, then close it. Make sure to prepare water containers.

Step 2: Check Hydraulic Balance

OperationSpecific methodsThings to note
Adjust main valveClose all valves first and open them one by one from nearest to far10 minutes apart each time
Balance valve adjustmentClockwise reduces flow, counterclockwise increasesMake good mark records

Step 3: Pipe Flushing

For systems that are more than 3 years old, it is recommended to contact a professional to use a high-pressure water gun to flush the pipes and remove internal sediments.

3. Key points in processing different heating systems

System typeKey measuresProfessional advice
central heatingMainly exhaust and balanceDon’t release water privately
Wall mounted boiler systemCheck water pump pressureMaintain 1.5bar pressure
Floor heating systemDivider adjustmentIndividual exhaust for each channel

4. Some effective tips tested by netizens

1. The "tapping method" on Douyin Heat Transfer: Use a rubber hammer to gently tap the pipe to help the air bubbles move

2. The "temperature adjustment method" hotly discussed on Weibo: first adjust all radiators to the highest temperature, and then adjust after running for 2 hours

3. The "Towel Wrapping Method" recommended by Xiaohongshu: Wrap the non-heated parts with a wet towel to help heat conduction

5. When does it require professional maintenance?

If the problem is still not solved after trying the above methods, it may be due to the following situations, and it is recommended to contact a professional:

- Heating system has not been maintained for over 10 years

- Hear obvious abnormal sound of water flow

- Multiple sets of radiators are not hot at the same time

- Water leakage occurs

6. Preventive measures

timemaintenance itemsOperational points
Before heating every yearSystem checkTrial run 2 weeks in advance
During heatingExhaust gas regularly1-2 times a month
After stopping heatingFull water maintenanceMaintain system pressure

Through the above systematic analysis and solutions, I believe it can help you effectively solve the problem of no heat at the end of the heater. Remember, regular maintenance is key to maintaining effective heating.

Next article
  • What should I do if the end of the heater is not hot? A summary of popular solutions across the networkWith the arrival of winter, lack of heating has become a headache for many families. Especially the end of the heater is not hot, which affects the overall heating effect. This article combines the hot discussions and expert suggestions on the Internet in the past 10 days to sort out a set of system solutions for yo
    2025-11-29 mechanical
  • What is a manual spring testing machine?In the fields of industrial production, quality inspection and scientific research, spring performance testing is crucial. As a common testing equipment, the manual spring testing machine is widely used to test the compression, tension, stiffness and other properties of springs. This article will introduce in detail the definition, working principle, application scenarios and c
    2025-11-26 mechanical
  • What is a weather resistance testing machine?In today's industrial production and scientific research fields, weathering testing machines, as an important environmental simulation equipment, are widely used in material aging testing, product performance evaluation and other fields. This article will introduce in detail the definition, working principle, application scenarios and comparison of popular models on the ma
    2025-11-24 mechanical
  • What is a 200-ton hydraulic universal testing machine?In the fields of industrial production, materials science and engineering testing, the 200-ton hydraulic universal testing machine is an important equipment used to test the mechanical properties of materials. This article will introduce its definition, application scenarios, technical parameters and market trends in detail, and provide you with a comprehensive an
    2025-11-21 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line